Switch 3 through 5: Data, Parity and Stop Bit
Switches 3 through 5 are used to specify the data, parity and stop
bits. The following table shows the settings that may be used:
Switches 6 through 8: Frequency and Data Rate
Switches 6 through 8 determine the frequency and data rate. The
following chart shows the settings that may be used:
6
1200 OFF OFF ON
2400 ON OFF ON
4800 ON ON OFF
9600 OFF ON ON
19200 ON ON ON
38400 OFF OFF OFF
57600 ON OFF OFF
115200 OFF ON OFF
Model 2036 and 2037
Data Rate SW6 SW7 SW8
7B EP 1S ON ON ON
7B OP 1S OFF ON ON
7B NP 2S ON OFF ON
7B EP 2S OFF OFF ON
7B OP 2S ON ON OFF
8B EP 1S OFF ON OFF
8B OP 1S ON OFF OFF
8B NP 1S OFF OFF OFF
Stop
Data Parity Bit SW3 SW4 SW5
4.0 INSTALLATION
The Patton Model 2036 and 2037 are very simple to install. Once
you have configured the DIP switches, just plug your converter in to a
standard cable and you’re ready to go. Figure 3 illustrates the proper
connections for the Model 2036 and 2037. If you have special-ordered
a non-standard connector, your connections may be different.
7
Figure 3. Installing the Model 2036
Model 2036 or 2037
PC
Printer
Your cable